Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. microfossil analysis 1 mg of foodcrust
  2. Proteomic analysis 10 mg of foodcrust
  3. bulk stable isotopeanalysis(with EA-IRMS) ca 5 mg offoodcrust;
  4. lipid residue analysis, ca 20 mg foodcrust; at least 0.5 g of homogenised ceramic powder for acid extraction, and around 1 g for solvent extraction.


Proteomics Data Workflow  

Data Acquisition and Export 

Data Processing with LC-MS 

Analysis Scripts and Computational Tools (MaxQuant, MetaMorpheus 

Lipid Data Workflow

In lipid analysis we usually have three steps of workflow generating a series of raw data -> interpreted data -> integrated data. 

  • Data Acquisition and Export (GC-FID, GC-MS, GC-SIM, GC-C-IRMS) 

GC-FID and GC-MS (scan and SIM) data is generated by masshunter software. 

For example, there is a sequence of measurements. 

 Image Removed

Each measurement will generate a folder containing a series of raw data (method acquisition file and data files). 

Image Removed

GC-C-IRMS data is generated by Qtegra. 
Each sequence produces a single container file (.imexp) that contains all the measurement data. It is not possible to extract individual measurements from this file. The .imexp format can only be opened with Qtegra® software.

Image Removed

After initial checks and corrections in Qtegra®, the relevant data is exported to .xlsx format for calibration and for general accessibility.

Image Removed

It's also possible to export all chromatogram data points, allowing graphs to be reconstructed in Excel (.xlsx) or ohter programs as well. 

 Image Removed

...

Image Removed

Image Removed

...

Data reliability/limitation of method 

...

Data Workflow  

Lipid Data Workflow

...

Microfossil Data Workflow

...